Home > Products > Glass Insulator > AC ANSI Glass Insulator
Product Description
Compared to ceramic materials, glass disc insulators have high dielectric strength.
Glass disc insulators have high resistivity and a low coefficient of thermal expansion.
Compared to porcelain insulators, they have higher tensile strength.
● Application: Suitable for transmission and distribution lines;
● Advantage: The surface of glass insulator has high mechanical strength, and the surface is not easy to crack and the aging speed is slow, no need to measure insulation resistance during operation, low operation and maintenance costs;
● Applicable Standard: IEC, GB, BS, ANSI, AS, or Customer's requirement;
Type |
Diameter (mm) |
Structural Height (mm) |
Creepage Distance (mm)
|
ANSI Level |
Coupling Size (mm) |
Mechanical& Electrical Strength (kN) |
Tension Proof (kV) |
Mechanical Impact Strength (N-m) |
Low Frequency Dry Fleshover Voltage (kV) |
Low Frequency Wet Fleshover Voltage (kV) |
Min power Frenquency Puncture Voltage (kV) |
Net Weight Per Unit (kg) |
U70B/146A |
255 |
146 |
320 |
52-3-L |
Type B |
70 |
35 |
45 |
80 |
50 |
130 |
3.8 |
U100B/146A |
255 |
146 |
320 |
52-3-H |
Type B |
100 |
50 |
45 |
80 |
50 |
130 |
3.8 |
U120B/146A |
255 |
146 |
320 |
52-5-L |
Type J |
120 |
60 |
45 |
80 |
50 |
130 |
4.0 |
U120BP/146A |
280 |
146 |
450 |
52-5 |
Type J |
120 |
60 |
45 |
100 |
60 |
130 |
5.5 |
U140B/146A |
255 |
146 |
320 |
52-5-H |
Type J |
140 |
70 |
45 |
80 |
50 |
130 |
4.0 |
U160B/146A |
280 |
146 |
400 |
52-8-L |
Type K |
160 |
80 |
45 |
85 |
55 |
130 |
7.0 |
U160BP/171HA |
330 |
171 |
550 |
52-8 |
Type K |
160 |
80 |
45 |
105 |
65 |
130 |
9.0 |
U180B/146A |
280 |
146 |
400 |
52-8-H |
Type K |
180 |
90 |
45 |
85 |
55 |
130 |
7.0 |
U230B/156A |
280 |
156 |
400 |
52-3-L |
Type K |
230 |
115 |
45 |
85 |
55 |
130 |
7.0 |
U70C/146A |
255 |
146 |
320 |
52-4-L |
Clevis |
70 |
35 |
45 |
80 |
50 |
130 |
4.0 |
U100C/146A |
255 |
146 |
320 |
52-4-H |
Clevis |
100 |
50 |
45 |
80 |
50 |
130 |
4.0 |
U120C/146A |
255 |
146 |
320 |
52-6-L |
Clevis |
120 |
60 |
45 |
80 |
50 |
130 |
4.0 |
U140C/146A |
255 |
146 |
320 |
52-6-H |
Clevis |
140 |
70 |
45 |
80 |
50 |
130 |
4.0 |
U160C/146A |
280 |
146 |
400 |
52-10-L |
Clevis |
160 |
80 |
45 |
85 |
55 |
130 |
7.0 |
U180C/146A |
280 |
146 |
400 |
52-10-H |
Clevis |
160 |
90 |
45 |
85 |
55 |
130 |
7.0 |
U230C/156A |
280 |
156 |
400 |
52-12 |
Clevis |
180 |
115 |
45 |
85 |
55 |
130 |
7.0 |
Order Information: ①Voltage grade; ②Specified mechanical load; ③Creepage distance; ④Power frequency withstands voltage; ⑤Lightning impulse withstands voltage; ⑥Insulation distance; ⑦Coupling type |